The correct way to disassemble and assemble the IMC magnetic pump is as follows:
1. Disconnect the power supply and empty the medium in the pump, prepare the necessary maintenance tools and replacement parts, and do not knock the pump body indiscriminately during the disassembly process;
2. Be careful not to reverse the dismantling sequence, first dismantle the auxiliary equipment of the magnetic pump, and then dismantle the pump body from the outside to the inside;
3. First disassemble the coupling and make positioning marks, check and record the concentricity and axial clearance of the coupling, and then disassemble the auxiliary pipeline, pump cover and shaft head nut in turn;
4. Use both hands to take out the impeller, disassemble the coupling and then measure the end cover of the shaft seal, disassemble the coupling and move the motor to the side. The rotor can be pulled outward, and the coupling can be beaten with a pure copper rod if necessary. Before taking out the pump shaft, the sealing gland can be disassembled, and the bearings at both ends can be disassembled according to the situation;
The above is the correct way to disassemble and assemble the conventional type of magnetic pump. Different types of magnetic pump have different internal structures, so the details of the actual operation are different. It is recommended to operate according to the actual model. For complete grasp, you can directly consult the technical customer service in the station to obtain professional and detailed technical guidance.